Sorry we couldn't be helpful. Help us improve this article with your feedback. Connect to the datalogger - AP_XXXXXXXXXX, 3. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This article is a guide for how to replace a Solis Data Logger on an existing system: one that has already been created in SolisCloud. Hi Everyone, I got some help with the Ginlong Wifi and I have been able to set the system up and log onto the Ginlong monitoring websitebut the system says it is 'loading' but no data is shown on the site. I haven't been able to log onto it after many attempts. on solis S3-WIFI WiFi Stick Datalogger Installation Guide, solis GPRS Stick Datalogger Instruction Manual. Solis Inverter Data Logger Issue : r/solar - reddit.com Yes String Inverters | Energy storage inverters - Solisus - Ginlong Solis Data Logger Server Information - firewall exceptions Modified on Fri, 09 Dec 2022 at 02:15 PM When the network environment of the plant has a firewall, you need to add the server information to the white list of the firewall. AGL replaced the data logger a few months back and it has worked perfectly since then. When configured correctly (see below), Solis invertors will send data about their performance every 5 minutes to code waiting to receive the data. Verify the WIFI stick is broadcasting by looking for the WIFI transmitter AP_XXXXXXXXXX in your WIFI SSID connections. 2023 AGL recognises the Aboriginal and Torres Strait Islander peoples as the Traditional Owners of the lands on which we work, and we acknowledge those communities' continuing connections to their lands, waters and 1. Solis DLS-W WiFi Data Logger Installation Guide : Solis WiFi datalogger firmware is out of date In general you want to ensure the router is not blocking the IP address from the WIFI stick. The device must be installed away from the strong magnetic field produced by large electrical appliances such as microwave ovens, refrigerators, telephone, metal walls, etc. We have just had a solar system installed. Victor is the author of this solution article. Verify the address is set to "1". Then click Done. 2019-08-29 16:17:17. You will have full control of your system whenever and wherever you are. Scan the bar code on the logger [note: a cellular logger is shown in the photo but it has the same scanning process as the, You should see a message that says "Bound Successfully" and now you will need to set up the logger on the local, settings and then connecting to the network that starts with "AP" - this is the. An example of data being processed may be a unique identifier stored in a cookie. Gua rpida de instalacin del sistema de monitoreo para Mxico y Centro Amrica. To connect to the WIFI stick go to the WIFI connections and select the AP_XXXXXXX and connect. Firmware Version: 3.16.9. i have recently installed a solar inverter which has a data logger > having an issue connecting it to my wifi network but it works fine with . No, Modified on: Fri, Jun 10, 2022 at 11:55 AM. Router signal strength is low 4. No-Grid - El inversor no reconoce la red. Internal DC Short: In the inverter head, or the wirebox? Note: the SolisWiFilogger can only connect to 2.4 GHz networks and is unable to connect to 5 GHz networks. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. Step 3: Confirm the plant information.Click Create a plant.Step 4: Click View plant to enter the plant homepage, then add the datalogger. S-Energy 320W modules, Terminal Torque Specs by Inverter Model Series, Advisory Bulletin July 2019 - New DC Switch Color of Red on Single Phase, Application Notes: Rapid Shutdown AC Wiring with Multiple Inverters, Rule 21 Phase 1 July 26th Changes 1P and 3P, Solis RSD Letter For Jurisdiction Acceptance, Spring Terminals Installation and Removal, RHI-1P(5-10)K-5G with BYD HV Commissioning Guide, Solis RHI-1P(5-10)K-HVES-5G Installation Guide, 5 of 20 - Installing the External Meter and CTs, 7 of 20 - Inverter Menu Overview and Selecting the Grid Standard, 8 of 20 - Installing & Commissioning the BYD B-Box HV Battery, 9 of 20 - Installing LG Chem RESU10H Battery (Mounting), 10 of 20 - Installing LG Chem - Wiring and Commissioning, 11 of 20 - Energy Storage Operating Modes - Self Use, 12 of 20 - Energy Storage Operating Modes - Feed-In-Priority, 13 of 20 - Installing the Solis Autotransformer, 14 of 20 - Installing the Backup Loads Subpanel and Selecting Critical BreakersLoad, 15 of 20 - Energy Storage Operating Modes - Backup and Off-Grid Modes, 17 of 20 - Module-Level Rapid Shutdown (MLRSD), 18 of 20 - SolisCloud Monitoring Platform, Installation Overview & Single-Line Diagrams, Solis Inverter Alarm Codes (Complete List), NO-Grid Fault - The inverter does not recognize the AC grid, Firmware Updating Guides & Firmware Files, Solis Inverter Current Firmware Versions [Master List], RHI-1P(5-10)K-HVES-5G inverters DSP firmware updating process, RHI-1P(5-10)K-HVES-5G inverters HMI firmware updating procedure, Solis-1P(3.6-10)K-4G inverters DSP firmware updating process, Solis-1P(3.6-10)K-4G inverters HMI firmware updating process, Solis-(25-40)K-4G inverter DSP firmware updating procedure, Solis-(25-40)K-4G inverter HMI firmware updating procedure, Solis-(50-66)K-4G inverters DSP firmware updating procedure, Solis-(50-66)K-4G inverters HMI firmware updating procedure, Solis-(75-100)K-5G-US inverter DSP Firmware Updating Procedure, Solis-(75-100)K-5G inverter HMI Firmware Updating Procedure, Solis-125K-EHV-5G inverter DSP firmware updating procedure, Solis-125K-EHV-5G inverter HMI firmware updating procedure, Solis-(185-255)K-EHV-5G inverter DSP firmware updating procedure, Solis-(185-255)K-EHV-5G inverter HMI firmware updating procedure, Setting a custom (user-defined) grid standard, US Grid Standards (values) // confidential //. If you have not already been registered on SolisCloud, please see Step 18: SolisCloud . Thanks Peter. Solis Data Loggers : Solis Tap the Plant icon in the bottom left corner of the screen, Tap the plus sign in the top right corner and then tap "Add Plant", Fill in all of the required fields on the "Create Plant" page and then tap "Done" in the top right corner, Tap "Create Plant" to finish making a system inSolisCloud- tap "View Plant" once it gives you a big check mark, When the plant page opens, you will receive a message saying "No datalogger was added, please add a datalogger" tap "Add" if theWiFidata logger is plugged into the bottom of the inverter, A scanner will automatically come up. The setup process for the SolisWifiData Logger is fairly similar to the Cellular Data Logger's process. how to set up wifi stick in Solis inverter | Solis Data Logger Setup - YouTube 0:00 / 4:51 how to set up wifi stick in Solis inverter | Solis Data Logger Setup Infinite Laboratory. If the WIFI stick shows the inverter but you don't have data on the monitoring portal follow these steps: If it is not pingable verify the router password again. my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device", is it just the wifi (or has the whole system gone down) and will re-booting the system put it right. solis app gone off-line boards.ie - Now Ye're Talkin' Connect to the inverter (to get power) 3. I have done a bit of Googling and the only negative thing I have read about the data logger is that it can lose it's wifi connection easily. app on your phone. Connect to the datalogger - AP_XXXXXXXXXX 3. Step 2: Input the information about the plant as required. PDF c Ginlong Tech Ginlong Tech Preferred I'm Plant Owner Build Your Plant It used to come back eventually but sometimes I went up to the attic and just unplugged it from the inverter for a second and then put it back in. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Data Logger into the port and be sure to secure it by tightening the black connector. The decision to disable the feature was made via a poll last year. i cannot connect my solar wifi data logger to my wifi but it gets Open the Local Connection Status, click. Screenshot of the Status page in the configuration interface. If its not either move the inverter closer to the router, the router closer to the inverter or use a repeater to boost the strength. Yes Well also assume you agree to the way we use cookies and are ok with it as described in our Privacy policy, unless you choose to disable them altogether through your browser. Solarman Data Loggers (4-pin only) DLS-W: WiFi only data logger; DLS-L: LAN only data logger; DLS-C: 4G cellular only data logger; Solis is no longer selling these products in the US; Our distributors likely still have stock of these products but we are not promoting them; Solarman loggers do not support remote settings changes or firmware updates This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. Things (IOT). 2: On the computer, click on the Network Connections and select the Local Connection. Step 5: Scan the SN number of the datalogger or manually input it.Note: Scan the datalogger SN, NOT the inverter SN. No-Grid - El inversor no reconoce la red. on Properties, select internet protocol IPv4(TCP/IPv4). WiFi datalogger firmware is out of date. Step 6: Plant creation succeeds. You can select the corresponding server information according to the model of data logger used by the plant. Model: AP300 Hardware Version: V11. AGL replaced it free of charge. Solis WiFi Loggers Network Strength Requirements, Solis Home Professional - Generation 2 Monitoring Platform, Account Transfer to New Monitoring Platform, Adding End-User (Customer) to Plant for Monitoring Access, Selecting Inverter Drivers on AlsoEnergy PowerTrack Monitoring, Inaccurate Production Data on Monitoring Portal, Registering Installer Account on G2 Portal, Setting Up Agency Access to Plant Monitoring, Enabling SMS Notifications on SolisCloud App, How to Create an Installer Account on SolisCloud, Create Sub-Organizations, & Manage Sub-Accounts, Deteccin falla de arco y solucin de problemas, Pantalla en blanco / LCD en blanco / Sin luces. Continue with Recommended Cookies, Home solis solis S3-WIFI WiFi Stick Datalogger Installation Guide, WiFi Stick Datalogger QuickInstallation ManualVersion: 3.1. Thanks, The Boards Team. SolisCloud intelligent software enables systems to be commissioned, monitored and maintained remotely saving time and money for installers and empowering system owners with all the data they need. solis SOL-DLS-W Data Logger Wifi Stick Introduction Data Logger Wifi Stick Is mainly used: 10 inverters 10 realize simple and Quick access to Internet. Victor is the author of this solution article. Log in to the page , the username is "admin" and the password is also "admin" 5. 2. It may also be affected by lighting storms. it has come back on line, so it is obviously a connection issue, Xi Jinping must have forgot to reboot the GFW this morning, Copyright 2000- 2023 Boards Software Limited, If you have a new account but are having problems posting or verifying your account, please email us on, Hello All, This is just a friendly reminder to read the Forum Charter where you wish to post before posting in it. If there are symbols in the password, it must be changed or the logger will not connect to it. Dataloggers can be scanned or added manually by entering in the serial number. cordless phone, concrete wall, PV panel and metal wall, to ensure the communication quality. If you hate cookies, or are just on a diet, you can disable them altogether too. Solis monitoring system is centered around photovoltaic power station, focusing on service operation and maintenance, Remotely controlled,adopting plug and play connection. It came with a Ginlong data logger wifi stick that I have set up according to the instructions. Select Network, fill in the IP address assigned by the router/network administrator, 1: Connect LAN stick to operational inverter to provide power to LAN stick. 3: Set a manual IP for the computer using the following information -, (The IP of the computer must be with 10.10.100.XXX range to configure the LAN stick). I'm having the same issue, just tried setting it up but says it's offline, light on the stick is red, anything I should be checking? Open a web browser and enter "10.10.100.254" into the address bar 4. Open navigation. After you connect verify the WIFI stick sees the inverter. My data logger turned out to be faulty. If you run through the setup wizard and are still having problems I suggest you contact them. If the connection is weak (1-2 bars) then it is recommended to install a. range extender to boost the signal strength where the logger is going to be. If you hate cookies, or are just on a diet, you can disable them altogether too. Step 1: Use your phone to scan the QR code to download and register the Solis Cloud APP. 4G Next COnfigurate Connection 15:30 Back Enter the plant name Done Plant Name 125K Multi-Input Inverter: No Paralleled DC Strings Allowed! Copyright@2019 Ginlong Technologies All rights reserved, Dec-17-2019, Go Solis Webinar: 2020 CA Solar Mandate Compliance with Solis Inverters, Feb-11-2020, Go Solis Webinar: New Solis 125K 1500V Inverters plus AlsoEnergy: Better ROI for 2-40 MW Systems, Mounting, Wiring, and Commissioning 4G Single Phase Inverter - Video, Solis and the Tigo TS4 Platform; Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Contacting Technical Support for Solis Partners, Contacting Technical Support for Your Region, Go Solis 2020 Webinar #7: Testing Solis Inverters Beyond Certifications with PV Evolution Labs, Go Solis Mini Exchange#1: An Introduction to Energy Storage System, Go Solis Webinar #1: 2020 California Solar Mandate with Solis Inverters (12/17/2019, U.S.), Go Solis Webinar #2: The New Solis 125K 1500V Inverters plus Also Energy (2/11/2020, U.S.), Go Solis Webinar #3: Solis Hybrid Energy Storage Inverter with LG Chem (2/11/2020, U.S.), Go Solis Webinar #4: Solis Commercial Inverters (4/21/2020, U.S.), Go Solis Webinar #5: Solis inverters and SunSpec Alliance (5/5/2020, U.S.), Go Solis Webinar #6: Solis and Tigo TS4 Platform - Tested and Harmonized Commercial Inverter 690.12 Rapid Shutdown Solutions, Go Solis Webinar #8 Solis Inverters and SunSpec Alliance: The Importance of SunSpec CSIP 2030.5, Ginlong Solis: Standard Lead Time from Ningbo to USA/Canada, How to Determine the Firmware Version of your Solis Inverter, Lowering Output Power of Single Phase Solis Inverter, MA Compatibility Between Single Phase 4G and 2G inverters, Solis 3PH and CSI GS Product Number and Description 20180331, Starting Serial Numbers and HMI VER- ISO-NE / Rule 21 P1 and P3, String Sizing for 1P and 3P Inverters. Step 3: Manually fill in the datalogger SN or Scan the SN on the datalogger. Step 5: Long press the Reset button for 5 seconds until the yellow and green LEDs are quickly flashing. You will need to have theSolisCloudapp downloaded on your phone. signal at the inverter for there to be a stable connection. Start by pulling up the site on SolisCloud - tap "Plant" in the bottom left corner and then find the desired site in the . Solis Monitoring. Have contacted the company who sold me it. The [RESET] button on the back is used for the connection. Reset instruction for Solis Datalogger - YouTube solis app gone off-line MATTYON Apr 14, 2022 hi all my Solis app has stopped giving info since about 1 am with message "Current plant offline, Please check network connection of plant device" i wont get to it until tonight has anyone seen this before is it just the wifi (or has the whole system gone down) and will re-booting the system put it right The replacement is working brilliantly. Yes You can rerun the wizard and see if that works. We use cookies to try and give you a better experience in Freshdesk. Thanks for your help, my data logger looks like it is faulty. You will need to have the, Unscrew the protective cap over the green COM port on the bottom of the inverter's wire box. first report in, so please wait until the system begins to show data on. Administrators, Computer Games Moderators, Sports Moderators, https://www.boards.ie/discussion/comment/118925467#Comment_118925467, https://www.boards.ie/discussion/comment/118925665#Comment_118925665, https://www.boards.ie/discussion/2058241657/solis-app-gone-off-line, https://www.boards.ie/discussion/comment/118926624#Comment_118926624, Music Production Commercial According to the website my data logger is offline. Shows the power supply status of the datalogger. Plug the provided charging cable into Skyroam Solis and connect to a power source. Communication quality may be affected in lightning storms. The delay in putting it in place was due to a bug/update issue. Verify the RSSI (signal strength) is higher than 15%. Connect the data logger to the corresponding 4-pin COM port of the inverter. Solis monitoring system can be monitored remotely by WIFI and GPRS to provide users accurate and comprehensive data analysis and fault alarm at any time and place, this makes product operation more stable and reliable, and realize stable and intelligent operation and maintenance management services.
How To Sleep With Hyperextended Knee, Articles S